16 Configuration
To rename a channel globally
Right-click on the channel name in the Channels window and click
Rename.
This will rename the channel where it is generated as well as in all the
places where it is used.
Configuration Tree
The Configuration Tree is used to configure the Global Setup, Input Pins,
CAN Inputs, Conditions, CAN Outputs, Keypad buttons and Output Pins.
The input and output pins will be numbered according to the PDM type
selected.
Global Setup
The Global Setup in the configuration tree is used to
Enter the PDM type and serial number
Configure the CAN addresses and timeout periods for incoming CAN
messages
Configure Master Retry and Master Shutdown channels for output pins
Configure Keypad settings for CAN keypads
PDM Type and Serial Number
The PDM type (PDM32, PDM16 etc.) and serial number must be configured
correctly before a new configuration file can be sent to a PDM.
A configuration can only be sent to the matching PDM to ensure the correct
configuration of PDMs in applications with multiple PDMs.
Output Pins Master Retry
The Master Retry feature turns all outputs that are in error back on. If there is
still a fault on a particular output, this output will go into error again and will go
through the normal retry sequence.
To initiate a Master Retry by pressing a button
Wire a button to a switch input
Use the channel generated by this input as the trigger channel for the
Master Retry.